Sign In | Join Free | My burrillandco.com
Home > Bypass Switch >

Anti DDoS Protector Inline Bypass TAP Detect Heartbeat Message Respond

Chengdu Shuwei Communication Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Anti DDoS Protector Inline Bypass TAP Detect Heartbeat Message Respond from wholesalers
     
    Buy cheap Anti DDoS Protector Inline Bypass TAP Detect Heartbeat Message Respond from wholesalers
    • Buy cheap Anti DDoS Protector Inline Bypass TAP Detect Heartbeat Message Respond from wholesalers

    Anti DDoS Protector Inline Bypass TAP Detect Heartbeat Message Respond

    Ask Lasest Price
    Brand Name : NetTAP®
    Model Number : NT-FBYP-L1G
    Price : Can Discuss
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 100 sets per month
    Delivery Time : 1-3 Working Days
    Certification : CCC, CE, RoHS
    • Product Details
    • Company Profile

    Anti DDoS Protector Inline Bypass TAP Detect Heartbeat Message Respond

    Inline Bypass Network TAP Detect Heartbeat Message Respond for Anti DDos Protector

    1. Anti DDos Protector Bypass TAP Intelligent Heartbeat Message Detection Technology


    Define Heartbeat Messages

    The heartbeat packets of the NetTAP® policy traction protector default to Ethernet Layer 2 frames. When deploying transparent Layer 2 bridging mode (such as IPS / FW), Layer 2 Ethernet frames are normally forwarded,blocked or discarded. At the same time, NetTAP® policy traction protector also supports custom heartbeat message format to meet the situation that some special serial security devices can not normally forward ordinary Layer 2 Ethernet frames.

    The NetTAP® Policy Traction Protector also supports heartbeat packet detection based on VLAN tag, Layer 3 and Layer 4 custom message types. Based on this mechanism, the user can implement a service safety test function of the connection safety device to make it more effective to ensure that the corresponding security services work properly.

    NetTAP® "Strategic Traffic Traction Protector" can also support the monitor to send different heartbeat packets in both directions. For example, TCP and UDP type heartbeat packets are customized on the "Strategy Traffic Traction Protector", according to the particularity of the serial device. You can configure the sending of TCP heartbeat packets on the uplink monitor A port and the sending of UDP heartbeat packets on the downlink monitor B port to accommodate the message forwarding mechanism of the serial security device. This function can more effectively guarantee the string. Connect the safety equipment to normal operation.


    2. Intelligent Anti DDos Protector Application Solution​
    Based on the dynamic strategy of traffic traction security detection protection
    "Bypass Switch" Another advanced application scenario is based on the dynamic strategy of traffic traction security detection protection applications, the deployment of the way as shown below:

    Take the "anti-DDoS attack protection and detection" security testing equipment, for example, through the front-end deployment of "bypass switch" and then anti-DDOS protection equipment and then connected to the "bypass switch", in the usual " Traction protector "to the full amount of traffic wire-speed forwarding at the same time the flow mirror output to the" anti-DDOS attack protection device ", once detected for a server IP (or IP network segment) after the attack," anti-DDOS attack protection device " will generate the target traffic flow matching rules and send them to the "bypass switch" through the dynamic policy delivery interface. The "bypass switch" can update the "traffic traction dynamic" after receiving the dynamic policy rules Rule pool "and immediately" rule hit the attack server traffic "traction to the" anti-DDoS attack protection and detection "equipment for processing, to be effective after the attack flow and then re-injected into the network.

    The application scheme based on the "bypass switch" is easier to implement than the traditional BGP route injection or other traffic traction scheme, and the environment is less dependent on the network and the reliability is higher.

    "Bypass Switch" has the following characteristics to support dynamic policy security detection protection:

    1,"bypass switch" to provide outside the rules based on WEBSERIVCE interface, easy integration with third-party security devices.

    2,"bypass switch" based on the hardware pure ASIC chip forwarding up to 10Gbps wire-speed packets without blocking switch forwarding, and "traffic traction dynamic rule library" regardless of the number.


    3,"policy flow traction protector" built-in professional BYPASS function, even if the protector itself failure, can also bypass the original serial link immediately, does not affect the original link of normal communication.



    3. Anti DDos Protector Bypass TAP Technical Specifications

    Product modelSpecifications
    NT-FBYP-L1X-SR1U chassis, 1*10GE multimode optical protection link
    NT-FBYP-L1X-LR1U chassis, 1*10GE single-mode optical protection link
    NT-FBYP-L1G-SX1U chassis, 1*GE multi-mode optical protection link
    NT-FBYP-L1G-LX1U chassis, 1*GE single mode optical protection link
    NT-CBYP-L1G1U chassis, 1*GE electrical protection link
    NT-CBYP-L2G1U chassis, 2*GE electrical protection link
    NT-FBYP-L2G-SX51U chassis, 2*GE multi-mode optical protection link
    NT-FBYP-L2G-LX1U chassis, 2*GE single-mode optical protection link
    NT-FCBYP-L4XG-SR1U chassis, 2*GE electrical protection link, 1*GE multi-mode optical protection link, 1*10GE multimode optical protection link
    NT-FCBYP-L4XG-LR1U chassis, 2*GE electrical protection link, 1*GE single mode optical protection link, 1*10GE single mode optical protection link

    2*GE Optical BYPASS Links(NT-FBYP-L2G)


    Product ModelNT-FBYP-L2G
    Interface formSFP slot4 * SFP slot, support 1000BASE-LX / SX module, support 1000BASE-T optical module
    SFP+ slot-
    GE optical BYPASS link2 link,4*1Gbase-SX multimode interface

    Deploy

    mode

    Number of link protection linksMaximum support for 2 GE optical BYPASS link
    MonitorMaximum support 2 GE optical / electrical link monitor
    Index parameterMulti-mode insertion loss1.1dB to 1.6dB
    Multimode emission optical power-9dB to -4dB
    Multimode receive optical power≥-18dB
    Multimode operating wavelength850nm
    Multimode transmission distance300M
    Single mode short insertion loss1.1dB to 1.6dB
    Single mode short distance emission optical power-9dB to -3dB
    Single mode short distance receiving optical power≥-24dB
    Single mode short working wavelength1310nm
    Single mode short distance transmission distance20KM
    Single mode mid - range insertion loss1.1dB to 1.6dB
    Single mode mid - range emitting optical power-5dB to 0dB
    Single mode mid - range received optical power≥-25dB
    Single mode midpoint working wavelength1310nm
    Single mode distance transmission distance40KM
    Single mode long distance insertion loss1.1dB to 1.6dB
    Single mode long distance emission optical power0dB to 5dB
    Single mode long distance receiving optical power≥-26dB
    Single mode long distance working wavelength1550nm
    Single mode long distance transmission distance80KM
    Functional performanceTotal number of interfaces8
    Line speed processing capacity8Gbps
    Cross - link protection based on IP / protocol / port quintuple specific trafficSupport
    Based on the total flow of the series protectionSupport
    Multi - channel load balancing functionSupport
    Custom heartbeat message functionSupport
    Ethernet encapsulation supportSupport
    BYPASS switching functionSupport
    Bypass switch without flashSupport
    CONSOLE network managementSupport
    IP/WEB network managementSupport
    SNMP V1/V2C network managementSupport
    TELNET/SSH network managementSupport
    SYSLOG protocolSupport
    User authentication functionBased on user name and password authentication
    ElectricRated supply voltageAC-220V/DC-48V【Optional】
    Rated power frequency50HZ
    Rated input currentAC-3A / DC-10A
    Rated Power40W
    EnvironmentWorking Temperature0-50℃
    Storage temperature-20-70℃
    Working humidity10%-95%,No condensation
    User configurationconsole configurationRS232 interface,9600,8,N,1
    Outside network management interface1*10/100/1000M Ethernet interface
    Password authenticationSupport
    DimensionChassis dimension (U)1U 485mm*44.5mm*350mm
    Product Tags:

    anti ddos protector

      
    Quality Anti DDoS Protector Inline Bypass TAP Detect Heartbeat Message Respond for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Chengdu Shuwei Communication Technology Co., Ltd.
    *Subject:
    *Message: